Precast concrete stairs installed on site, with straight flights and a landing

Technical guide

Precast staircase design guide

A design guide to precast concrete staircases for architects, engineers and builders: key stair terms, the main Building Regulations dimensions, and how precast flights and landings are designed, made and installed.

Written bySouthcrete technical teamUpdated3 October 2026

Please note: this guide is general information to help with planning. Every project is different: always follow your structural engineer’s design, the manufacturer’s instructions and the current Building Regulations.

Why precast concrete stairs?

Precast concrete stairs are manufactured off-site and lifted into place, rather than formed and cast on site. Each flight is made in controlled factory conditions, giving consistent dimensions and finish, and the stair can be used soon after installation, with no formwork or curing time on site. Southcrete stairs are reinforced precast concrete, made to your architect’s drawings.

Key stair terms

Rise
The vertical height of one step.
Going
The horizontal depth of one step, measured from nosing to nosing.
Pitch
The angle of the stair relative to the horizontal.
Flight
A continuous run of steps between landings.
Landing
A level platform at the top, bottom or part-way up a stair.
Waist
The thickness of the concrete slab beneath the steps.
Headroom
The clear height above the pitch line of the stair.
Nosing
The front edge of a tread.

Building Regulations: key dimensions

Stairs in England must meet Approved Document K (protection from falling, collision and impact). For a private stair in a dwelling, the main figures are:

Maximum rise220mm
Minimum going220mm
Maximum pitch42°
Twice the rise plus the going (2R + G)Between 550mm and 700mm
HeadroomAt least 2.0m

Stairs serving buildings other than dwellings, and common stairs in blocks of flats, have tighter limits on rise and going. Rises and goings must be consistent throughout a flight. Requirements for width, landings, handrails and guarding also apply, and fire safety requirements under Approved Document B may affect escape stairs.

This table is a summary for early design. Always check the current Approved Documents and your Building Control body for your building type.

Stair configurations

Straight flight stairs

A single run of steps between two floors, or between floor and landing. Simple to design, make and install.

Dog-leg stairs

Two flights running in opposite directions, joined by a half landing. Common in houses and blocks of flats where floor-to-floor heights are too great for one flight.

Landings and intermediate landings

Precast landings link flights and turn the stair. Intermediate landings break up long runs and may be required by the Regulations where a flight would otherwise have too many risers.

Custom designs

Non-standard layouts can be manufactured to suit the architect’s drawings, subject to structural design and practical lifting weights.

Structural design and bearings

Precast flights and landings are reinforced concrete elements designed by a structural engineer for their spans and loads. Flights typically bear onto landings, floor slabs or supporting walls at each end. The bearing details, any connections to the surrounding structure, and allowances for tolerances should be agreed during design so the stair fits first time.

Information needed for design

  • Architectural drawings and sections through the stairwell
  • Finished floor-to-floor heights and the build-ups of floor finishes
  • Stairwell width and length, and the required stair width
  • Building type and use, so the correct Part K category is applied
  • Landing positions and how the stair bears onto the structure
  • Required finish, nosings and any handrail or balustrade fixing positions

Finishes and fixings

Precast stairs can be left as cast or finished with applied coverings. Anti-slip nosings, handrail and balustrade fixings should be agreed before manufacture so their positions can be planned into each flight.

Installation

  1. Confirm the opening and bearing levels against the drawings.
  2. Deliver by HIAB: each flight is lifted from the lorry and positioned.
  3. Set and secure each flight and landing on its bearings as designed.
  4. Protect the stair during the rest of the build, particularly treads and nosings.
  5. Fit handrails and guarding before the stair is put into general use.

Compare methods in precast vs in-situ concrete stairs.

Before you start

Precast Staircase Design checklist

  • Floor-to-floor heights confirmed, including finishes
  • Rise, going and pitch within Part K for the building type
  • Headroom checked along the full flight
  • Landing positions and bearings agreed
  • Finishes, nosings and fixings agreed before manufacture
  • Access for HIAB delivery and lifting checked

FAQ

Precast Staircase Design questions

Are your precast stairs reinforced?

Yes. Southcrete precast stairs are reinforced concrete, manufactured off-site to your architect’s drawings.

What is the maximum rise for a private stair?

Approved Document K gives a maximum rise of 220mm and a minimum going of 220mm for a private stair, with a maximum pitch of 42°. Always check the current guidance for your building type.

Can you make landings?

Yes. Precast landings and intermediate landings can be made to link flights and turn the stair.

What do you need to design a precast stair?

Drawings and sections of the stairwell, finished floor-to-floor heights, stair width, building type and landing positions.

Get a quote

Ask our technical team

Tell us about your project and attach your drawings. Our estimating team will come back with a detailed quote and layout plan.

Not sure what to send? Read what we need for a quote.

Request a quote

We only use your details to reply to your enquiry.