Please note: this guide is general information to help with planning. Every project is different: always follow your structural engineer’s design, the manufacturer’s instructions and the current Building Regulations.
What is a beam and block floor?
A beam and block floor is a suspended concrete floor made from prestressed concrete beams spanning between load-bearing walls, with infill blocks laid between the beams. Once the joints are grouted, the beams and blocks act together as a solid structural deck, ready for insulation and a screed or floating floor finish.
Because the floor spans between walls rather than bearing on the ground, it is widely used for ground floors on poor, sloping or shrinkable ground, near trees, and wherever a ground-bearing slab would need deep fill. It can also be used for upper floors, subject to the structural design.
Components of the system
Prestressed concrete beams
The beams have an inverted-T profile, which is why they are often called T-beams. The projecting “nibs” along the bottom carry the infill blocks. Southcrete manufactures beams in 150mm and 225mm depths and in 50mm length increments, each labelled with its manufacture date, size and weight.
Infill blocks
Concrete infill blocks sit on the beam nibs and fill the gaps between beams. The block type is set out on the floor layout plan. Southcrete supplies the beams only; infill blocks are sourced separately to the specification on your layout plan.
Grout
Once all beams and blocks are in place, the joints are filled by brushing in a sand and cement slurry. This locks the floor together so it behaves as one deck.
Finishes
The structural floor is normally finished with insulation and a screed or floating floor, designed to meet the thermal and acoustic requirements of the building.
Information needed to design the floor
Every beam and block floor is designed for its building. To prepare an accurate floor layout plan and quote, the designer needs:
- Architectural floor plans showing all load-bearing walls and clear spans
- The positions of internal partitions, especially heavy or load-bearing partitions
- Soil and vent pipes (SVPs), drainage and other service penetrations
- Any loads beyond normal domestic use, such as heavy finishes, plant or storage
- Whether the floor is a ground floor or an upper floor
- Any information about ground conditions or ground gas protection required on the site
From this, the layout plan shows the beam depth, the position and length of every beam, the infill block arrangement and the details around partitions and services, together with structural calculations for Building Control.
Beam depth, spacing and spans
The beam depth and spacing are chosen to suit the clear span and the loads. Longer spans or heavier loads generally need deeper beams or beams placed closer together.
Heavy partitions running parallel to the beams are usually carried on additional or doubled-up beams beneath them, rather than on infill blocks alone. Point loads and openings in the floor are dealt with in the layout design.
For typical maximum spans, download our 150mm and 225mm beam span and load tables.
Span tables are for planning only. Spans and loads are specific to each project, so always use the floor layout plan and structural calculations prepared for your building.
Bearings and the substructure
Beams must sit on level, sound bearings with the bearing length shown in the design. Before delivery, check that:
- The bearing walls are built to the correct level and line, and the mortar has gained strength
- Spans measured on site match the layout plan; report any differences so the plan can be updated before manufacture
- Damp-proof courses are in place where your design requires them
- Any required ground gas or radon protection has been allowed for in the design
Ventilation and the void beneath
Suspended ground floors are built over a void. The depth of the void, its ventilation and the treatment of the ground beneath should follow your design and Approved Document C of the Building Regulations, which covers site preparation and resistance to moisture and ground contaminants.
Make sure ventilation openings, sleeved through walls where needed, are not blocked by later works such as paths, patios or landscaping.
Services and openings
Services passing through the floor, such as SVPs and drainage, should be shown on the drawings so the layout can leave the right gaps between beams. Beams must never be cut, notched or drilled on site; if something changes, contact the designer so the layout can be revised.
Insulation and thermal performance
Beam and block floors are normally insulated above the blocks, with rigid insulation boards and a screed or floating floor, to reach the U-value required by Approved Document L. The insulation thickness depends on the product used and the target U-value set by your designer or energy assessor.
Upper floors
Beam and block can also be used for upper floors in houses and other buildings, subject to the structural design. The same principles apply: a layout plan, structural calculations, proper bearings and attention to partitions and openings. Southcrete supplies and installs beam and block for both ground floors and upper floors.
Delivery, handling and storage
- Beams are delivered by HIAB lorry-mounted crane and placed close to where they will be laid
- Store beams the right way up, on level bearers, keeping them clear of the ground
- Lift beams as instructed; never lift or support them in ways that could crack or overload them
- Check each beam’s label against the layout plan before laying it
Installation sequence
- Check the substructure against the layout plan.
- Lay the beams in the positions shown, with the correct bearing at each end.
- Lay the infill blocks between the beams on the beam nibs, cutting where needed around edges and penetrations.
- Grout the joints with a sand and cement slurry.
- Hand over for insulation and screed or floating floor.
Getting ready for delivery? Read our beam and block delivery site checklist.