Please note: this guide is general information to help with planning. Every project is different: always follow your structural engineer’s design, the manufacturer’s instructions and the current Building Regulations.
What a lintel does
A lintel is a horizontal structural member spanning an opening, such as a door or window, carrying the wall and any floors or roof above it and transferring that load to the masonry either side.
Types of lintel
Prestressed concrete lintels
Made with tensioned steel strands cast into the concrete, which puts the lintel into compression and makes it strong for its size. Southcrete lintels are prestressed precast concrete, made to order.
Other types
Lintels may also be steel, reinforced concrete or composite. The type for each opening is set by your designer or engineer, based on the span, loads and wall construction.
What decides the size
- Clear span of the opening
- Loads above: masonry, floors, roofs and any point loads
- Wall thickness and whether the wall is solid or cavity
- Bearing length available at each end
- Fire, thermal and appearance requirements where relevant
Standard sizes suit many openings, but long spans, heavy loads, awkward bearings and non-standard wall thicknesses are where a bespoke concrete lintel made to your engineer’s specification is the better choice.
Bearings
Each end of a lintel must sit on sound, level masonry for the bearing length in the design. A minimum bearing of 150mm at each end is common for typical lintels, but longer spans and heavier loads may need more, and some bearings need a padstone. Always follow the bearing length on your drawings or calculations.
Install the right way up
Prestressed lintels are designed to work one way up. They are marked to show the top face, and must be installed with the marked face uppermost. A prestressed lintel installed upside down can fail.
Lintels in cavity walls
In cavity walls, the inner and outer leaves each need support over the opening, either with separate lintels or a lintel designed for the cavity. External openings also need the right cavity tray and damp-proofing details above the lintel, and the arrangement should limit thermal bridging in line with Approved Document L.
Installation
- Check the opening width and bearing levels against the drawings.
- Bed the lintel on mortar on both bearings, level and with the top face uppermost.
- Check the bearing length at each end matches the design.
- Prop where required, and build masonry above evenly, allowing mortar to gain strength.
- Avoid point loads on the lintel during construction unless designed for.
Lintels must not be cut, notched or drilled unless the manufacturer and engineer confirm it is acceptable.
Replacing a steel lintel with concrete
Concrete can be used in place of a steel lintel where your structural engineer specifies it. Send the engineer’s design and Southcrete will manufacture a custom concrete lintel to suit the opening and loads.
What to send for bespoke lintels
Send your drawings or lintel schedule with the length, width, depth and quantity of each lintel, and any engineer’s calculations. Southcrete will manufacture to specification and deliver by HIAB, ready to install.